Infrared
Infrared
| Product | Description | Accuracy | Energetic consumption | Measurement range | Temperature range | Target Gas | Response Time | Output | Output formats | Temp. drift | Power Supply | Current Consumption (mA) | Output current | Reading per seconds |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
INFRA.sens® AK2 SF6 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<1 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analogic
|
||||||
|
INFRA.sens® AK20 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<1 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Output formats
RS232, Can, Analogica
|
Temp. drift
3 secondi (T90)
|
||||||
|
INFRA.sens® AK250TBH The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<100 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 secondi (T90)
|
Output
RS232, Can, Analogica
|
||||||
|
Infra.Sens AK100 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 1 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
||||||
|
Infra.Sens AK250 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 2000ppm
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
||||||
|
Infra.Sens AK5 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 100 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
||||||
|
Infra.Sens AK50 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 20 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
||||||
|
NEXT-PM Module for PM10/2.5/1.0 measurement based on proprietary Laser technology. UART output or RS485. |
Measurement range
0-1000 ㎍/㎥
|
Target Gas
PM2.5 / PM1.0
PM10
|
Output
UART
RS485
|
Power Supply
5.0 Vdc
|
Current Consumption (mA)
250 mA
|
||||||||
|
NEXT-PM Lite Compact size measurement module for particulate matter PM10/2.5/1.0 based on proprietary Laser technology |
Measurement range
0-1000 ㎍/㎥
|
Target Gas
PM2.5 / PM1.0
PM10
|
Output
UART
RS485
|
Power Supply
5.0 Vdc
|
Current Consumption (mA)
<50 mA
|
||||||||
|
ULTRA.sens® AK100 H2S The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<100 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Output current
RS232, Can, Analogic
|
Reading per seconds
3 seconds (T90)
|