Infrared
Infrared
| Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output | Energetic consumption | Temperature range | Response Time | Output formats | Temp. drift | Output current | Reading per seconds |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
C4H10-S3-3V NDIR module for the measure of Butane. |
Accuracy
± 2% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butano
|
Operating temperature
-20°C / +50°C
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
|||||||
|
INFRA.sens® AK2 SF6 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Measurement range
<1 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analogic
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||||||
|
INFRA.sens® AK20 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Measurement range
<1 Vol.%
|
Target Gas
Multigas
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Output formats
RS232, Can, Analogica
|
Temp. drift
3 secondi (T90)
|
||||||||
|
INFRA.sens® AK250TBH The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Measurement range
<100 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analogica
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 secondi (T90)
|
||||||||
|
Infra.Sens AK100 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Measurement range
< 1 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analog
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||||||
|
Infra.Sens AK250 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Measurement range
< 2000ppm
|
Target Gas
Multigas
|
Output
RS232, Can, Analog
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||||||
|
Infra.Sens AK5 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Measurement range
< 100 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analog
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||||||
|
Infra.Sens AK50 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Measurement range
< 20 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analog
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||||||
|
ULTRA.sens® AK100 H2S The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Accuracy
±2 % F.S.
|
Measurement range
<100 Vol.%
|
Target Gas
Multigas
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Output current
RS232, Can, Analogic
|
Reading per seconds
3 seconds (T90)
|
||||||||
|
ULTRA.sens® AK100 TBH The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Accuracy
±2 % F.S.
|
Measurement range
<100 Vol.%
|
Target Gas
Multigas
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Output current
RS232, Can, Analogic
|
Reading per seconds
3 seconds (T90)
|