Infrared
Infrared
| Product | Description | Power Supply | Measurement range | Target Gas | Output | Accuracy | Dimension | Humidity range | Working temperature | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|
|
PSML Infrared module for PM2.5/1.0 measurement based on proprietary IrED technology. UART LPO (Low Pulse Occupancy) |
Power Supply
5.0 Vdc
|
Measurement range
0-500 ㎍/㎥
|
Target Gas
PM2.5 / PM1.0
|
Output
LPO (Low Pulse Occupancy)
|
|||||
|
PSMU Infrared module for PM2.5/1.0 measurement based on proprietary IrED technology. UART output |
Power Supply
5.0 Vdc
|
Measurement range
0-500 ㎍/㎥
|
Target Gas
PM2.5 / PM1.0
|
Output
UART
|
|||||
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Power Supply
5.0 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
0°C / 50°C
|
|
|
T-110-3V As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application. |
Power Supply
3.3 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0-2%
0-3%
0-5%
0-10%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
0°C / +50°C
|
|
|
T-200 NDIR module for CO2 measurement |
Power Supply
5.0 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analogica (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|
|
|
T-200-3V NDIR module for CO2 measurement. |
Power Supply
3.3 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|
|
|
T-300A Miniature NDIR module for the measure of CO2. Designed for customers in residential buildings, offices, or cabin of vehicles, or so. |
Power Supply
5.0 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
PWM
|
Accuracy
± 25ppm ± 5% of reading
|
Dimension
19 x 31 x 7.9 mm
|
Humidity range
0-95% RH
|
Operating temperature
-10°C / +60°C
|
|
|
T-300A-3V Miniature NDIR module for the measure of CO2. Designed for customers in residential buildings, offices, or cabin of vehicles, or so. |
Power Supply
3.3 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
PWM
|
Accuracy
± 25ppm ± 5% of reading
|
Dimension
19 x 31 x 7.9 mm
|
Humidity range
0-95% RH
|
Operating temperature
-10°C / +60°C
|