Magnetostrictive transducers

Magnetostrictive transducers
Change view mode

GYPM

The sensor head of GYPM probe is more compact. Thanks to the new design of the probe head, the screw side dead zone has been shortened to 30mm (Standard). As to tip dead zone, making it short to 40mm is possible by option (standard: 70mm). Cable out direction is radial.

GYPM probe is used in combination with the GYHC or GYDC-05 controllers, which provide velocity output or digital output.

GYSE-A

The inside probe element can be detached from the outer housing (standard function for GYSE). Additionally, use of flexible element as an option makes the exchange process extremely easy even under small work space. Using two pcs of magnet on the probe as another option, makes detecting each magnet position or their relative distance possible.

With the captive software (GPM), zero and gain adjustment is possible at user side.

16 bit resolution, high performance analogue output.

GYSE-A-PF

The inside probe element can be detached from the outer housing (standard function for GYSE). Additionally, use of flexible element as an option makes the exchange process extremely easy even under small work space. Using two pcs of magnet on the probe as another option, makes detecting each magnet position or their relative distance possible.

GYSE-P

This magnetostrictive transducer uses a Profibus DP interface and allows the use of a maximum of 32 magnet on the same probe.

The element of the probe are detachable from the housing.

GYSE-P-PF

Resolution min. 1 µm, Profibus DP interface, detachable probe element, magnet max.32 pcs

Setting parameters (resolution, output) through profibus is possible.

GYSE-Q

Resolution Min. 1µm, A/B pulse incremental output, detachable probe element.

The working principle is based on a sampling detection method, in which pulse frequency is fixed to 250 kHz (Standard)

GYSE-Q-PF

Resolution min. 1 µm, A/B pulse incremental output, detachable probe element.

The working principle is based on a sampling detection method, in which pulse frequency is fixed to 250 kHz (Standard)

GYSE-R

Between probe and controller, RS422 differential line driver transmission, providing robustness against electrical noise, is used. In combination with GYDC-05 controller, Min. 1 µm  m resolution is possible.

GYcRP

High performance, providing robustness against electrical noise. In combination with GYDC-05 controller is possible 1µm resolution

GYcRS