Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
4NH3LL-100 3electrode electrochemical cell for ammonia detection. |
Life expectancy
About 2 years in air
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
<= 90 seconds
|
Output
30nA/ppm +/-20nA/ppm
|
|||||
|
D-300-3V NDIR module for the measure of CO2 |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 300ppm ± 3% of reading
± 30ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
EDI080120NG Guardian NG is a stand-alone analyzer for CO2, with infrared sensor technology. |
Measurement range
0-1000 ppm
|
Target Gas
Anidride Carbonica
|
Output
4-20 mA
0-20 mA
|
Power Supply
24V DC (18-30 V DC)
|
||||||
|
GS+4NH3-100 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
100 ± 30 nA/ppm
|
|||||
|
GS+4NH3-1000 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
8 ± 4 nA/ppm
|
|||||
|
GS+4NH3-300 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-300 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
40 ± 15 nA/ppm
|
|||||
|
GS+7NH3-100 Electrochemical cell for ammonia. Ideally for industrial application, in particular for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
115 ± 45 nA/ppm
|
|||||
|
GS+7NH3-1000 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
8 ± 4 nA/ppm
|
|||||
|
NH3 3E 100 City Technology - 3 Electrode Electrochemical Cell for Ammonia with organic electrolyte |
Life expectancy
> 18 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 120 seconds (T90)
|
Output
90 ± 40 nA/ppm
|
|||||
|
NH3 3E 100 SE City Technology - 3 Electrode Electrochemical Cell for Ammonia |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
130 ± 30 nA/ppm
|