Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Power Supply | Current Consumption (mA) | Application field | Heater consumption |
|---|---|---|---|---|---|---|---|---|---|---|
|
7HL City Technology - Electrochemical Cell for Hydrogen Chloride |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen Chloride
|
Response Time
< 120 seconds (T90)
|
Output
750 ± 250 nA/ppm
|
||||
|
HCl 3E 30 City Technology - Electrochemical cell for Hydrogen Chloride |
Life expectancy
> 24 months
|
Measurement range
0-30 ppm
|
Target Gas
Hydrogen Chloride
|
Response Time
< 70 seconds (T90)
|
Output
140 ± 60 nA/ppm
|
||||
|
NEXT-PM Module for PM10/2.5/1.0 measurement based on proprietary Laser technology. UART output or RS485. |
Measurement range
0-1000 ㎍/㎥
|
Target Gas
PM2.5 / PM1.0
PM10
|
Output
UART
RS485
|
Power Supply
5.0 Vdc
|
Current Consumption (mA)
250 mA
|
||||
|
NEXT-PM Lite Compact size measurement module for particulate matter PM10/2.5/1.0 based on proprietary Laser technology |
Measurement range
0-1000 ㎍/㎥
|
Target Gas
PM2.5 / PM1.0
PM10
|
Output
UART
RS485
|
Power Supply
5.0 Vdc
|
Current Consumption (mA)
<50 mA
|
||||
|
TGS2603 The TGS 2603 has high sensitivity to low concentrations of odorous gases such as amine-series and sulfurous odors generated from waste materials or spoiled foods such as fish. |
Target Gas
Air pollutants
1-10 ppm Ethanol
|
Application field
Air quality
|
Heater consumption
240 mW
|