Gas sensors
Gas sensors
| Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output | Application field | Heater consumption |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
C4H10-CD300 Transmitter board with NDIR sensor for Butane (C4H10) |
Accuracy
± 3% F.S.
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-100% LEL
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
||
|
C4H10-D3 NDIR module for the measure of Butane (C4H10) |
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 4.5V)
|
||
|
C4H10-D3-3V NDIR module for the measure of Butane (C4H10) |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 3.0V)
|
||
|
C4H10-LD-3V NDIR module for the measure of Butane. |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
||
|
C4H10-LF-3V NDIR module for the measure of Butane. |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
||
|
C4H10-S3 NDIR module for the measure of Butane. |
Accuracy
± 2% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
||
|
TGS2600 The TGS 2600 has high sensitivity to low concentrations of gaseous air contaminants such as hydrogen and carbon monoxide which exist in cigarette smoke. The sensor can detect hydrogen at a level of several ppm. |
Measurement range
1-30 ppm H2
|
Target Gas
Air pollutants
|
||||||||
|
TGS2602 The TGS 2602 has high sensitivity to low concentrations of odorous gases such as ammonia and H2S generated from waste materials in office and home environments. |
Measurement range
1-30 ppm Ethanol
|
Target Gas
Air pollutants
VOCs, ammonia, H2S
|
||||||||
|
TGS2603 The TGS 2603 has high sensitivity to low concentrations of odorous gases such as amine-series and sulfurous odors generated from waste materials or spoiled foods such as fish. |
Target Gas
Air pollutants
1-10 ppm Ethanol
|
Application field
Air quality
|
Heater consumption
240 mW
|
|||||||
|
TGS2610-C00 TGS2610 is a semiconductor type gas sensor which combines very high sensitivity to LP gas with low power consumption and long life. |
Measurement range
500-10.000 ppm
|
Target Gas
LPG
Butane
|
Application field
Automotive
|
Heater consumption
280 mW
|