City Technology
City Technology
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output |
|---|---|---|---|---|---|---|
|
3HYE City Technology - 3 Electrode Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 70 seconds (T90)
|
Output
3 ± 1 nA/ppm
|
|
3HYT City Technology - electrochemical cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 50 seconds (T90)
|
Output
30 ± 10 nA/ppm
|
|
3ND City Technology - Electrochemical Cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 35 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|
3NDH City Technology - electrochemical cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 40 seconds (T90)
|
Output
1.4 ± 0.3 μA/ppm
|
|
4ND City Technology - Electrochemical Cell for Nitrogen Dioxide NO2 |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 25 seconds (T90)
|
Output
600 ± 150 nA/ppm
|
|
5ND City Technology - Electrochemical Cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 60 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|
7HYE City Technology - Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 110 seconds (T90)
|
Output
3 ± 1 nA/ppm
|
|
7HYT City Technology - electrochemical cell fof Hydrogen |
Life expectancy
> 24 months
|
Measurement range
50-1000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 85 seconds (T90)
|
Output
30 ± 1 nA/ppm
|
|
A3OZ City Technology 4 Electrode environmental monitoring sensor for Ozone and Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-10 ppm
|
Target Gas
Ozone
Nitrogen dioxide
|
Response Time
< 40 seconds (T90)
|
Output
2.2 ± 0.5 μA/ppm
|
|
AQ3ND City Technology - Electrochemical cell for Nitrogen Dioxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
Output
1.029 ± 0.294 mV/ppb
|