Infrared
Infrared
| Product | Description | Power Supply | Measurement range | Target Gas | Output | Accuracy | Dimension | Humidity range | Operating temperature | Working temperature |
|---|---|---|---|---|---|---|---|---|---|---|
|
EDI080113NG Guardian NG is a stand-alone analyzer for CO2, with infrared sensor technology. |
Power Supply
from 90 to 260 VAC
|
Measurement range
0-5%
|
Target Gas
Carbon dioxide
|
Output
0-20 mA
4-20 mA
|
|||||
|
EDI080123NGDC uardian NG is a stand-alone analyzer for CO2, with infrared sensor technology. |
Power Supply
24V DC (18-30 V DC)
|
Measurement range
0-5%
|
Target Gas
Carbon dioxide
|
Output
4-20 mA
0-20 mA
|
|||||
|
EDI080202NG Guardian NG is a stand-alone analyzer for CH4, with infrared sensor technology. |
Power Supply
from 90 to 260 VAC
|
Measurement range
0-5%
|
Target Gas
Methane
|
Output
0-20 mA
4-20 mA
|
|||||
|
EDI080302NGDC Guardian NG is a stand-alone analyzer for CO2, with infrared sensor technology. |
Power Supply
24V DC (7-30V)
|
Measurement range
0-5%
|
Target Gas
Methane
|
Output
0-20 mA
4-20 mA
|
|||||
|
H-250-12V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Power Supply
12.0 Vdc
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
PWM
I2C
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Dimension
50 x 69 x 20 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|
|
H-250-3V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Power Supply
3.3 Vdc
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 300ppm ± 3% of reading
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|
|
H-250-5V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Power Supply
5.0 Vdc
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|
|
MT-200 Modulo USB NDIR per la misura di CO2 per Qualità dell'aria. |
Power Supply
USB
|
Measurement range
0-10000 ppm
0-5%
0-10%
|
Target Gas
Carbon dioxide
|
Output
USB
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
55.6 x 19.4 x 10.3 mm
|
Humidity range
0-95% RH
|
Operating temperature
-20°C / +60°C
|
|
|
S-300 NDIR module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Power Supply
5.0 Vdc
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Target Gas
Carbon dioxide
|
Output
PWM
UART
I2C
Analog (0.5V - 4.5V)
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
-10°C / 60°C
|
|
|
S-300-3V NDIR module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Power Supply
3.3 Vdc
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Target Gas
Carbon dioxide
|
Output
UART
I2C
PWM
Analog (0.5V - 3.0V)
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature